A large export coal mine had problems with microwave and admittance probes on blocked chute applications because of high dielectric magnetite build-up, coal fines build-up etc.

Problem applications included wet screens, transfer chutes, crushers, apron feeders etc

Hawk Measurement used the automatic cleaning acoustic Gladiator switch that removed build-up and was not affected by the high dielectric environment.

This acoustic switch is a dual transducer system unaffected by vibration, dust, water, high dielectric atmospheres and comes with UHMW and titanium wear plates.